Concrete cancer (spalling) occurs when embedded reinforcement corrodes, causing the surrounding concrete to crack, delaminate, and fall away. Our concrete cancer assessment service combines visual inspection, cover meter surveys, half-cell potential testing, and carbonation depth measurement to fully diagnose the extent of deterioration—delivering comprehensive reports with remediation strategies and cost estimates.
Delco Industries operates across Gold Coast, Brisbane, and all of South East Queensland, providing concrete cancer assessment services to structural engineers, principal contractors, builders, body corporates, and government agencies. Our reports are engineer-certified and accepted by all Queensland councils, certifying authorities, and structural engineering firms.
Every engagement is led by qualified structural and civil engineering professionals — not just field technicians. This means every data set is interpreted with an engineering lens, and every report you receive is ready to be used directly in structural decision-making. We comply with all relevant Australian Standards including AS 3600, AS 2159, AS 1012, and AS/NZS 1170.1 where applicable.
Queensland Coverage
Gold Coast (Surfers Paradise to Coomera) · Brisbane Metro · Logan · Ipswich · Sunshine Coast · Toowoomba · Regional QLD available on request.
Why Choose Delco
- → Engineer-certified reports — not just technician data
- → Same-day reporting as standard
- → Free quotes within 2 hours
- → Same-week site visits across SEQ
- → $20M public liability insurance
- → AS/NZS standards compliant
- → Accepted by all QLD councils
Related Guides
Input → Process → Output
Affected Structure
Multi-Method Diagnosis
Deterioration Extent Map
Corrosion Data
Carbonation & Cover Analysis
Remaining Life Estimate
Assessment Results
Remediation Engineering
Repair Strategy & Costing
What We Deliver
- Visual & photographic inspection
- Cover meter surveys
- Half-cell potential testing
- Carbonation depth measurement
- Chloride content testing
- Detailed remediation recommendations
Common Uses
- 01Balcony & façade assessments
- 02Car park structural reviews
- 03Strata building reports
- 04Insurance claim support
- 05Pre-purchase due diligence
- 06Remediation project scoping
Related Projects
Bridge Pier Structural Assessment
Ultrasonic pulse velocity testing and corrosion survey for critical infrastructure bridge piers.
Pile Integrity Testing - Multi-Storey
Foundation pile testing using impact echo technology for a new commercial development.
Concrete Delamination Survey
Amplitude heat mapping and delamination detection for parking structure assessment.
Concrete Cancer Assessment — Frequently Asked Questions
Concrete cancer (spalling) occurs when embedded reinforcement corrodes due to moisture, chloride ingress (especially near coastal areas), or carbonation of the concrete cover. The corrosion products expand, cracking and delaminating the concrete above — leading to dangerous spalling and structural weakening.
Request a Quote for
Concrete Cancer Assessment
Submit your project details and our team will provide a tailored quote within 24 hours. Free, no-obligation consultations available.